13
FIREPLACE COMPONENTS
SF42A
SF42A
SF42AI
SF42AI
SCF42A
SCF42A
SCF42AI
SCF42AI
S48
S48
S36
S36
S18
S18
S12
S12
SE30
SE30
SCS
SCS
SC
SC
SCL
SCL
SQL8
SQL8
612
612
1212
1212
SF
SF
SF-30
SF-30
FP-4-U
FP-4-U
403
403
AK4
AK4
GD42PB
GD42PB
GD42B
GD42B
FA2
FA2
H2066
H2066
JB1
JB1
S8
S8
CF8
CF8
MODEL
MODEL
30-degree elbows (package contains two 8-inch diameter elbows.)
30-degree elbows (package contains two 8-inch diameter elbows.)
Chimney support (required when chimney height exceeds 30 feet)
Chimney support (required when chimney height exceeds 30 feet)
Round chimney cap for contemporary installation, includes storm collar
Round chimney cap for contemporary installation, includes storm collar
Round telescoping chimney cap
Round telescoping chimney cap
Square telescoping chimney cap (18 1/2" x 18 1/2")
Square telescoping chimney cap (18 1/2" x 18 1/2")
0-6/12 pitch flashing for contemporary installation. One required with SC round
0-6/12 pitch flashing for contemporary installation. One required with SC round
chimney cap on 0-6/12 pitch roof.
chimney cap on 0-6/12 pitch roof.
6/12-12/12 pitch flashing for contemporary installation. One required with SC r
6/12-12/12 pitch flashing for contemporary installation. One required with SC r
ound chimney cap on 6/12-12/12
ound chimney cap on 6/12-12/12
pitch roof.
pitch roof.
14-1/2-inch firestop spacer - One required at each ceiling or floor level
14-1/2-inch firestop spacer - One required at each ceiling or floor level
Firestop spacer - 30" chimney incline through ceiling or floor
Firestop spacer - 30" chimney incline through ceiling or floor
4-inch uninsulated combustion air duct - 8-foot length
4-inch uninsulated combustion air duct - 8-foot length
4-inch duct connector (for splicing FP-4-U ducts, includes one connector and two
4-inch duct connector (for splicing FP-4-U ducts, includes one connector and two
clamps)
clamps)
4-inch outside combustion air assembly
4-inch outside combustion air assembly
Optional 42-inch polished brass glass door kit
Optional 42-inch polished brass glass door kit
Optional 42-inch black finish glass door kit
Optional 42-inch black finish glass door kit
Optional fan assembly - includes switch. Installs under fireplace by removing l
Optional fan assembly - includes switch. Installs under fireplace by removing l
ower grille panel of fireplace.
ower grille panel of fireplace.
(SCF42A & SCF42AI)
(SCF42A & SCF42AI)
Hearth extension - protects floor against sparks and radiant heat (Residential i
Hearth extension - protects floor against sparks and radiant heat (Residential i
nstallation) 20" x 66"
nstallation) 20" x 66"
Junction box - For Optional Blower Assembly Installation. Must be installed at
Junction box - For Optional Blower Assembly Installation. Must be installed at
the time of fireplace installation if the
the time of fireplace installation if the
model FA2 Fan is to be installed.
model FA2 Fan is to be installed.
Telescope assembly for use with telescoping chimney caps.
Telescope assembly for use with telescoping chimney caps.
Terra cotta chimney cap
Terra cotta chimney cap
(Must use with VFK)
(Must use with VFK)
42-inch non-circulating fireplace
42-inch non-circulating fireplace
42-inch insulated non-circulating fireplace with insulating outer wraps.
42-inch insulated non-circulating fireplace with insulating outer wraps.
42-inch circulating fireplace
42-inch circulating fireplace
42-inch insulated circulating fireplace with insulating outer wraps.
42-inch insulated circulating fireplace with insulating outer wraps.
4-foot chimney section (8-inch diameter flue)
4-foot chimney section (8-inch diameter flue)
3-foot chimney section (8-inch diameter flue)
3-foot chimney section (8-inch diameter flue)
18-inch chimney section (8-inch diameter flue)
18-inch chimney section (8-inch diameter flue)
1-foot chimney section (8-inch diameter flue)
1-foot chimney section (8-inch diameter flue)
DESCRIPTION
DESCRIPTION
53D9032. Rev 1 03/03