Minolta RAVL42 Fire Pit User Manual


 
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice
should be de-rated by 4% for every 1,000 feet to maintain the proper
ratio of gas to air. Improper orifice sizing may result in damage and
unsafe conditions. Changing the orifice should only be done by a quali
-
fied service technician. Contact your Lennox Hearth Products dealer for
proper orifice sizes.
4
ORIFICE SIZE/ALTITUDE ADJUSTMENT
Since there are always several potential sources of fire in any home, we
recommend installing smoke detectors. If possible, install the smoke
detector in a hallway adjacent to the room (to reduce the possibility of
occasional false activation from the heat produced by the appliance). If
your local code requires a smoke detector be installed within the same
room, you must follow the requirements of your local code. Check with
your local building department for requirements in your area.
SMOKE DETECTORS
Must conform with all local, state and national installation codes.
In the absence of local codes, the installation must conform with
National Fuel Gas Code ANSI Z223.1 - latest edition, also known
as NFPA 54 (In Canada, the current CAN/CSA B149.1 installation
code). Refer to the National Fuel Gas Code and local zoning and
code authorities for details on installation requirements.
Mobile home installations must conform with the Mobile Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (in Canada
CAN/CSA Z240 MH), or, when such a standard is not applicable,
the Standard for Mobile Home Installations, ANSI A225.1 - latest
edition.
Must be vented directly to the outside in accordance with the latest
edition of the National Fuel Gas Code and must never be attached
to a chimney serving a separate solid fuel burning appliance.
Has been certified for use with either natural gas or propane.
Is not for use with solid fuels.
Is approved for sitting rooms and/or bedrooms.
THE RAVELLE™ 42 FIREPLACE