Desa CF26PT Outdoor Fireplace User Manual


 
111410-01C
For more information, visit www.desatech.com
For more information, visit www.desatech.com
3
3
A
U
T
O
O
FF
ON
PRODUCT IDENTIFICATION
Figure 1 - Vent-Free Bay Front Compact Fireplace
Heater Controls
(Inside Door)
Screen
Fireplace
Cabinet
Logs
1. This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.
2. Do not place propane/LP supply tank(s) inside any structure. Lo-
cate propane/LP supply tank(s) outdoors (propane/LP units only).
3. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do not use any phone in
your building
immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions
if you cannot reach your gas supplier, call the fire department
4. This fireplace shall not be installed in a bedroom or bathroom.
5. Do not use this fireplace as a wood-burning fireplace. Use only
the logs provided with the fireplace.
6. Do not add extra logs or ornaments such as pine cones, ver-
miculite, or rock wool. Using these added items can cause soot-
ing. Do not add lava rock around base. Rock and debris could
fall into the control area of fireplace.
7. This fireplace is designed to be smokeless. If logs ever appear
to smoke, turn off fireplace and call a qualified service person.
Note:
During initial operation, slight smoking could occur due
to log curing and fireplace burning manufacturing residues.
8. To prevent the creation of soot, follow the instructions in Clean-
ing and Maintenance, pages 17 and 18.
9. Before using furniture polish, wax, carpet cleaner, or similar
products, turn heater off. If heated, the vapors from these prod-
ucts may create a white powder residue within burner box or
on adjacent walls or furniture.
10. This fireplace needs fresh air ventilation to run properly. This
fireplace has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the fireplace if not enough
fresh air is available. See Air for Combustion and Ventilation,
pages 4 through 6. If fireplace keeps shutting off, see Trouble-
shooting, pages 19 through 21.
11. Do not run fireplace
where flammable liquids or vapors are used or stored.
under dusty conditions.
12. Do not use this fireplace to cook food or burn paper or other
objects.
13. Do not use fireplace if any part has been under water. Immedi-
ately call a qualified service technician to inspect the room
fireplace and to replace any part of the control system and any
gas control which has been under water.
14. Turn off and unplug fireplace and let cool before servicing. Only
a qualified service person should service and repair fireplace.
15. Operating fireplace above elevations of 4,500 feet could cause
pilot outage.
16. Do not operate fireplace if any log is broken. Do not operate
fireplace if a log is chipped (dime-sized or larger).
17. To prevent performance problems, do not use propane/LP fuel
tank of less than 100 lbs. capacity (propane/LP units only).
18. Provide adequate clearances around air openings.
Brick Liner
Keep the appliance area clear and free from combus-
tible materials, gasoline, and other flammable vapors
and liquids.
You must operate this fireplace with a fireplace screen
in place. Make sure fireplace screen is in place before
running fireplace.
SAFETY INFORMATION
Continued
SAFETY INFORMATION
PRODUCT IDENTIFICATION