Weber 300 Gas Grill User Manual


 
WWW.WebeR.com
®
33
mAINTeNANce
1
2
1
2
WEBER
®
SPIDER/INSECT SCREENS
Your Weber
®
gas grill, as well as any outdoor gas appliance, is a target for spiders and
other insects. They can nest in the venturi section (1) of the burner tube. This blocks the
normal gas flow, and can cause the gas to flow back out of the air shutter. This could
result in a fire in and around the air shutter, causing serious damage to your grill.
The burner tube air shutter is fitted with a stainless steel screen (2) to prevent spiders
and other insects access to the burner tube through the air shutter openings.
We recommend that you inspect the Spider/Insect screen at least once a year.
Refer to “ANNUAL MAINTENANCE.” Also inspect and clean the the Spider/Insect
screen if any of the following symptoms should ever occur:
A) The smell of gas in conjunction with the burner flames appearing yellow and lazy.
B) Grill does not reach temperature.
C) Grill heats unevenly.
D) Burner does not ignite.
m DANGER
Failure to correct the above mentioned symptoms may result
in a fire, which can cause serious bodily injury or death, and
cause damage to property.
BURNER TUBE CLEANING OR REPLACEMENT
You will need a flathead screwdriver.
A) Your Weber
®
gas barbecue must be OFF and cool.
B) Turn gas OFF at source.
C) Open lid and remove the cooking grates.
Burner Tube Removal
D) Remove the 1/4 x 20 inch screw that holds the burner tube to the cookbox (1).
E) Rotatetheoutsideburner90°.Slideandliftburnerawayfromburnerorificeand
remove from cookbox.
F) Repeat this procedure for the inside burner (2).
1
2
3
4
1
2
54