Viking viking Gas Grill User Manual


 
29
5
6
Bubbling bubbles in the soap solution indicates that a
leak is present.
Stop a leak by tightening the loose joint or by
replacing the faulty part with a replacement part
recommended by the manufacturer.
7
2
8
1
Do not attempt to repair the cylinder valve if it should
become damaged. The cylinder must be replaced.
If you are unable to stop a leak, shut off the gas
at the cylinder valve. Remove the cylinder from the grill.
Call an authorized gas
appliance service technician
or LP/Propane gas dealer.
Do not use the grill until
the leak is corrected.
OF
F
1
2
9
After checking for leaks, push in and turn any control
knob to release the pressure in the hose and manifold.
Turn off the control knob.
28
1
OF
F
2
Make a soap solution of one part liquid detergent and
one part water. You will need a spray bottle, brush or
towel to apply the solution to the fittings.
Note: For LP/Propane units, check with a full cylinder.
Check that all control knobs are in the “OFF” position.
4
Apply the soap solution to fittings.
Turn cylinder valve knob counter clockwise one
turn to open.
Although all gas connections on the grill are leak
tested at the factory prior to shipment, a
complete gas tightness check must be performed
at the installation due to possible mishandling in
shipment or excessive pressure unknowingly
being applied to the unit. Periodically check the
whole system for leaks, or immediately check if
the smell of gas is detected.
Do not smoke while leak testing.
Extinguish all flames.
Never leak test with an open flame
CAUTION
Before placing into operation, always check for
gas leaks with a soapy water solution. DO NOT
USE AN OPEN FLAME TO CHECK FOR LEAKS.
Leak Testing