Vanguard VI33PRA Fire Pit User Manual


 
110150-01B
For more information, visit www.desatech.com
For more information, visit www.desatech.com
23
23
WIRING DIAGRAMS
SPECIFICATIONS
REPLACEMENT PARTS
SERVICE HINTS
TECHNICAL SERVICE
A
U
T
O
O
F
F
ON
Thermopile
WIRING DIAGRAMS
Note
: For proper operation of optional accessories, the wires from
the switch to the control must be connected exactly as shown in
Figure 42.
Figure 42 - Switch Wiring Diagram
Red
Variable
Fan Switch
Fan Switch
(N.O.)
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
Black
Blue
Figure 43 - Blower Wiring Diagram
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
SPECIFICATIONS
VI33NRA VI33PRA
Btu (Variable) 20,000/30,000 20,000/33,000
Type Gas Natural Gas Only Propane/LP Only
Ignition Piezo Piezo
Pressure Manifold 3.5" W.C. 8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum 10.5" 14"
Minimum* 5" 11"
* For input adjustment
REPLACEMENT PARTS
Note:
Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply
original replacement part(s), call DESA International’s Technical
Service Department at 1-866-672-6040. When calling DESA Inter-
national, have ready
your name and address
model and serial numbers of your heater
how heater was malfunctioning
type of gas used (propane/LP or natural gas)
purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original
replacement part(s), call DESA International at 1-866-672-6040 for
referral information. When calling DESA International, have ready
model number of your heater
the replacement part number
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specified heat
for propane/LP unit, propane/LP gas supply may be low
You may feel your gas pressure is low. If so, contact your local gas
supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA International’s Technical
Service Department at 1-866-672-6040. When calling please have
your model and serial numbers of your heater ready.
You can also visit DESA International’s technical services web site
at www.desatech.com.