Vanguard VI33PRA Fire Pit User Manual


 
110150-01B
For more information, visit www.desatech.com
For more information, visit www.desatech.com
16
4. Press in and turn control knob clockwise to the
OFF position.
5. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information in column 2, page 15. If
you don’t smell gas, go to the next step.
6. Press in and turn control knob counterclockwise
to the PILOT position. Press in control knob for five (5)
seconds (see Figure 32).
Note:
You may be running this heater for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
7. With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure.
8. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
If control knob does not pop out when released, contact
a qualified service person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 4 through 8.
9. Slightly push in and turn control knob counterclockwise
to the ON position.
10. Wait one minute and switch selector switch to the ON posi-
tion to light burners.
11. Set flame adjustment knob to any level between HI and LO.
OPERATING FIREPLACE
INSERT
Continued
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
Figure 32 - Control Knob and Ignitor Button Location (Shown as
Supplied, No Control Options)
O
F
F
P
I
L
O
T
O
N
L
O
I
H
AUTO
OFF
ON
Control Knob
Ignitor Button
Selector Switch
Flame Adjustment
Knob
WARNING: Make sure the selector switch is in the
OFF position when you are away from home for long
periods of time. Heater will come on automatically
with selector switch in the ON position.
Ignitor
Electrode
Pilot
Burner
Figure 33 - Pilot
TO TURN OFF GAS
TO APPLIANCE
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting Instructions, page 15
and column 1.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
steps 9 through 11, column 1.
Shutting Off Heater
1. Turn control knob clockwise to the OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set remote selector
switch in the OFF position to keep from draining battery.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one
of the following:
Turn control knob clockwise to the PILOT position.
Use remote control manual OFF button.
Set remote selector switch in the OFF position.
OPERATING FIREPLACE INSERT
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
Natural Gas
Propane/LP Gas
Pilot
Burner
Ignitor
Electrode