Regency I31-NG3 Fire Pit User Manual


 
19
Regency I31-3 Gas Fireplace Inbuilt
FAN MAINTENANCE
If your fan requires maintenance or replace-
ment, access to the fan is through the plate on
the rear wall of the firebox. NOTE: the unit
MUST NOT be operated without the fan
access panel securely in place.
CAUTION: Label all wires prior to
disconnection when servicing
controls. Wiring error can cause
improper and dangerous opera-
tion.
Remove the 2 screws holding the
grate in position.
Remove the 2 screws,
push Burner Tray to the left, and lift off.
MAINTENANCE
10) Unplug the black wires from the fan motor
(from inside the stove).
11) Lift Fan Assembly off of the 2 pins, tip
forward and pull through firebox opening.
12) Disconnect green wire from power cord.
Replacing fan:
Reverse above steps. Hint for pushing fan
down onto pins - rub a bit of dish soap on the
grommet so it will slide more easily onto the pin.
Check to make sure the fan is seated properly
on the pins, this is very important- try to move
the fan back and forth, there should be no
noise, if there is check that the grommets
haven't come loose.
To remove fan:
1) Turn the unit off and allow it to cool to room
temperature.
2) Unplug or disconnect power source to
stove.
3) Remove glass front (see page 10).
4) Remove logs.
5) Remove brick panels.
6) Remove the Grate by removing the screws
on each side of the grate.
7) Remove the Burner Tray by removing the
screws on each side of the tray. Push the
tray to the left and lift up.
8) Remove the 11 screws holding the Access
Panel in place.
9) Remove the Fan Air Duct by removing 4
screws, 2 per side.
GLASS GASKET
If the glass gasket requires replacement use
7/8" flat glass gasket (Part # 936-243) for the