Hearth and Home Technologies CARDOG42I Outdoor Fireplace User Manual


 
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. Q • 7/11 17
A. Mantel Projections
Figure 7.1 shows the dimensions for mantels or other com-
bustible projections above the replace opening.
Fireplace Structure
Noncombustible mat’l
Mantel
25 in.
(635 mm)
minimum
Ceiling or
Overhang
12 in. (305 mm)
max. combustible
mantel depth
Figure 7.1 Clearances to Mantels or other Combustibles above Appliance.
7
7
Finishing
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as speci ed. Framing or nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc.).
B. Facing Material
The appliance can be covered with any noncombustible
material. Refer to Section 1.D.
It is possible for the face of the unit above the replace open-
ing to show signs of soot. Clean that area as frequently as
necessary to eliminate a build up of soot or permanent dis-
coloration. A noncombustible ledge (shelf) approximately 3
inches above the opening and a minimum of 3 inches out
from the face of the unit incorporated into the facing material
will help prevent the soot from going up the wall.
Note: The control box lid can be painted as desired.
Use sandpaper or other abrasive material to scuff
the surface prior to painting.