Harman Stove Company DVC-500 Outdoor Fireplace User Manual


 
31




The DVC-500 operates with a negative pressure
rebox as a safety feature. The control continuously
adjusts the draft motor speed to maintain a safe
rebox negative static.
: Observe the intensity of the Draft Motor light
on the control panel in comparison with the Feed
Motor light when it is on. When the appliance and
venting system are clean, the indicator light is much
dimmer than the others. This is because there is
lower voltage owing to the draft motor. As ashes
build up, the light will get brighter because the draft
motor needs to run faster in order to maintain the
negative pressure in the rebox. When the indicator
light for the draft motor appears as bright as the
rest of the lights, it is a good indication that it's time
to clean the appliance and the venting.
If the circuit board is owing full line voltage to the
Draft Motor, and the negative pressure in the rebox
is too low, the following safety protocol will begin.

When the safety switch senses a loss of negative
pressure in the rebox for more than 68 seconds
the following happens:
The combustion blower will reduce in speed.
During this cool down period the feeder is allowed
to opreate. If needed, the feeder can opreate for
up to 3 minutes.
After 72 minutes, if the safety switch has not sensed
another pressure loss, the unit will automatically
go back to the control board setting.
If the safety switch senses a loss of negative
pressure anytime during the STAGE 1 Protocol, the
unit automatically goes to the STAGE 2 Protocol

If Stage 1 has already begun and the negative
pressure is lost:
The status light will start to blink ( 2 blinks ).
The combustion blower and feeder motor will shut
off. These motors will remain off for a 5 minute cool-
down period. After ve minutes, those components
will restart at a reduced feed rate ( 30 seconds
max.) for 72 minutes.
After 72 minutes, if the safety switch has not sensed
another pressure loss, the unit will automatically
go back up to Stage 1.
The status light will continue to blink (2 blinks)
throughout Stage 1 and Stage 2.
If the safety switch senses a loss of negative
pressure anytime during the Stage 2 Protocol, the
unit automatically goes to the Stage 3 Protocol.

During stage 2, if another loss of negative pressure
is sensed;
The status light will continue to blink 2 blinks.
The Distribution Blower will be cycling "high" to
"low" as an audible warning.
The Combustion Blower and Feeder Motor will
shut off.
When the unit reaches Stage 3 these motors will
not restart.
The Draft Motor will continue to run at maximum
voltage, but the re will go out.




Resetting a 2 Blink Status likely indicates
that service is required.
Clean the appliance and the venting
system thoroughly. If the error persists,
contact your dealer for more advanced
service.