Harman Stove Company DVC-500 Outdoor Fireplace User Manual


 
26


The ESP (Exhaust Sensing Probe) is a temperature
sensing probe located in the exhaust outlet. The
ESP works with the Control to perform all burn
rate functions as well as high and low limit control.

The Room Sensor is a small temperature sensor
placed where you would normally put a thermostat.
The Room Sensor is extended to the stove with
normal thermostat wire. The Room Sensor works
with the ESP and the Control to provide the right
size re.

The FSS (Firebox Static Sensor) is an electronic
pressure sensor reading the rebox pressure. The
FSS works with the ESP Control to adjust the draft
blower speed to compensate for wind and changing
house pressures.

The TCP (Temperature Control Probe) is located
on the left side of the feeder. The TCP works with
the Control to reduce the feeder temperature if the
temperature begins to rise.
ESP
This sensor is located in the control box
behind the control board. It is preset and is
non-adjustable.
FIREBOX STATIC
FSS 1-10-163
TCP
Stove
X
1-10-163
SENSOR

TCP