Turn the Feed Adjuster to "Test" mode, (g. 13.)
This will cause all motors to run 100% for 2 minutes.
The lights on the control panel will be lit for each
motor. If you leave it on "test" the blowers will cycle
as an audible reminder.

1. Fill the hopper with dry coal. 

2. Fill burn-grate area from rebrick to front of grate
with about one inch of (DRY) coal.
3. Plug into 120 volt AC outlet and turn control to
"OFF". Turning to "OFF" and then back to the
desired mode resets the control.
4.Turn Feed Adjuster to the # 3 position, g. 14.
5. Make a valley in the coal at the top of the burn
grate. Fill valley with re starting material (coal
starter, crushed charcoal, wood pellets).
6.Turn Mode Selector to Room Temp or Stove
Temp as desired.
7. Turn the Temp Dial to the desired setting.
8. Light the re and make sure that all doors and
the hopper lid are closed. As the ESP senses the
correct temperature, the Feed Motor will start.

To kill the re or stop burning the stove, turn the
Mode Selector knob to the "OFF" position. This
will stop the feeder and the re will burn out. When
the stove cools to about 95 degrees Fahrenheit, all
motors will stop. The unit can then be unplugged.



        




All ash and partially burned coal must be cleaned
out from behind grates down under rebrick until
fresh coal is seen. Follow "Starting Fire" procedure
above.
Fig. 15
1
2
5
#3 Feed Adjustment setting
Test Position
g. 13