Harman Stove Company DVC-500 Outdoor Fireplace User Manual


 
15
Feed Adjuster
Sets the maximum feed
rate, 1 to 5
Test
Runs all motors at full
speed for two minutes
to check operation.
After two minutes the
feeder stops and the
distribution blower
alternates from high to
low every four seconds
to remind you that you
are still in "Test Mode".
Distribution Blower
speed adjustment
range.
Temp Dial
Allows you to adjust the room temperature
in Room Temp Mode using the outer scale
marked in degrees Fahrenheit. It also allows
you to adjust the stove temperature while
in Stove Temp Mode using the inner scale
marked from 1 to 7.
Mode Selector
Allows you to choose between Room
Temp Mode, Stove Temp Mode, or OFF.
Also allows you to vary the Distribution
Blower speed by turning the knob to the
"high" or "low" side of each mode.
Power Light
Indicates power is "on"
to the control.
Indicates power to
Distribution Blower
Indicates power to the
Feed Motor.
Indicates power to
Combustion Blower
Status Light
Will be lit in either Stove
or Room Temp Mode
when pointer is not
within "off" position band
except after normal shut
down. Blinks to indicate
errors listed below.
Ash Removal
position
See page 19

Indicates power to the
Draft Motor.
2 Blinks: Indicates that there is insufcient negative pressure
in the rebox. This begins a shut-down process described in
more detail on Page 31.
The most common cause of the 2 blink status is leaving the
ash door open without turning the Feed Adjuster to "Ash Out".
For other causes of a 2 blink status see Page 32.
This requires a Manual Reset*.
3 Blinks: Indicates that the ESP (Exhaust Sensing Probe) has
gone out of range a specied number of times. If the stove
seems to be performing normally, perform a Manual Reset*.
4 Blinks: Can occur only in Room Temp Mode and indicates
Room Sensing Probe has failed or is not installed. If a
Room Sensing Probe is then installed, the status light will
automatically reset.
5 Blinks: Indicates a lack of communication between the
circuit board and the TCP (Temperature Control Probe). This
requires a manual reset*.
* Manual Reset: Disconnect power cord for a few seconds
and reconnect. If error still occurs call your Dealer.

g. 12
DDM Port
Allows service technician to
attach diagnostic meter when
troubleshooting or verifying proper
operation.