Stovax PR0696 Fire Pit User Manual


 
SERVICING INSTRUCTIONS
SERVICING
18
This appliance must be serviced at least once a year by a
competent person.
All tests must be serviced by best practice as described by
the current CORGI recommendations.
1.1 Before any tests are undertaken on the appliance, conduct a
gas soundness test for the property to ensure that there are
no gas leaks prior to starting work.
1.2 Before any tests are undertaken on the appliance it is also
recommended to fully check the operation of the appliance.
1.3 Special checks
1.3.1 Clean any lint or fluff from the pilot - pay particular
attention to the aeration hole in the side of the pilot.
1.3.2 Clean away any fluff or lint from under the burner
1.3.3 Check that the spark gap on the pilot is correct.
1.4 Correct any faults found during the initial tests and then
recommission the appliance conducting the usual safety
checks.
1.5 Advise the customer of any remedial action taken.
1.6 As part of the annual service, the space behind the firebox
must be inspected for any debris, which may have fallen
down the chimney.
1.7 Remove the gas fire from the firebox as detailed below.
1.8 Inspect the space behind the firebox for debris and the
condition of the chimney, the flue flow test should be carried
out now. Remove any debris and carry out any necessary
remedial work.
1. SERVICING REQUIREMENTS