Stovax PR0696 Fire Pit User Manual


 
13
3
AR1154
5.4 Gas pipe entry must come through the right hand side of
the box. The rubber seal must be cut using a sharp knife to
allow the isolating elbow to pass through it. Ensure the
rubber is not damaged when doing this.
A means of isolation is provided with the appliance. This
must be fitted to the supply pipe prior to installing the
firebox.
6.INSTALLATION OF THE APPLIANCE
6.1 Ensure that the fireplace opening is in compliance with the
requirements of section 2 Site Requirements then proceed
as follows:
A) CABLE RETENTION METHOD
6.2 Mark the position of the 4 fixing holes on the rear of the
fireplace opening and drill the holes using a No. 12 masonry
drill bit. Insert the 4 fibre rawl plugs and screw the eyebolts
in as far as possible leaving the eye horizontal. See diagram 4.
4
AR1205
AR1204
Hotbox
Convector
75 75
75 75
465
48
328
24
6.3 Pass the 2 cables through the holes in the bracket on the
back of the firebox and pull taut so that the stop ends sit
tightly against the top of the bracket. See diagram 5.
5
AR1155 AR1156
Hotbox
Convector
6.4 Pass the cables vertically through the 2 sets of eyebolts and
thread the ends through the holes in the lower back of the
firebox. Pass the gas supply pipe through the hole in the
rubber seal (refer to section 5.2) and push the appliance into
place.
6.5 Thread the cables through the tensioner bolts and push the
threaded portions through the holes in the firebox so that
the lock nut sits against the back wall (ensure that the nut is
screwed fully up to the head of the tensioner to allow
maximum adjustment).
6.6 Slide the locking nipples onto the cables, pull the cables taut
and tighten the locking screw. Adjust the lock nuts using a
10mm spanner until the silicone sealing strip forms a tight
seal between the fireplace opening and the firebox flange.
See diagram 6.
6
AR1157
6.7 Coil up the surplus cable and locate in the back of the
fire box.
NEVER SHORTEN THE CABLES, THEY WILL BE REQUIRED
WHEN SERVICING THE APPLIANCE.
INSTALLATION INSTRUCTIONS
INSTALLATION