Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
Part # 4526884 Rev 4 (10/08/10)Page 6
Model
Total
kW
Load
Loading kW/Phase Nominal Amps Per Line
208/220/240V 3ph
208V 220V 240V
TB
1-Ph 3-Phase Delta 1-Ph 3-Phase Delta 1-Ph 3-Phase Delta
X-Y X-Z Y-Z L1-L2 X Y Z L1-L2 X Y Z L1-L2 X Y Z
XG36S 12.99 4.00 4.99 4.00
1 41.63 37.43 33.30 37.43 39.36 35.38 31.49 35.38 36.08 32.43 28.90 32.43
2 20.82 – – – 19.68 – – – 18.04 – – –
XG362S-L/R 8.66 2.66 3.33 2.66 1 41.63 24.93 22.14 24.93 39.36 23.57 20.94 23.57 36.08 21.61 19.19 21.61
3-Phase
Models
LINE
Total
kW
Load
Loading kW Per Phase Nominal Amps Per Line
208/220/240V 3ph 208V 3-Phase Delta 220V 3-Phase Delta 240V 3-Phase Delta
X-Y X-Z Y-Z L1 (X) L2 (Y) L3 (Z) L1 (X) L2 (Y) L3 (Z) L1 (X) L2 (Y) L3 (Z)
XE36S TB1 17.30 6.07 5.97 5.27 50.10 47.22 46.80 47.36 44.65 44.24 43.42 40.92 40.56
TB2 8.30 3.03 2.63 2.63 23.61 23.61 21.93 22.32 22.32 20.73 20.46 20.46 19.00
XE362S-L TB1 13.12 4.73 4.45 3.93 38.25 36.13 34.94 36.17 34.16 33.03 33.15 31.32 30.28
TB2 8.30 3.03 2.63 2.63 23.61 23.61 21.93 22.32 22.32 20.73 20.46 20.46 19.00
DIMENSIONS AND SPECIFICATIONS
Garland products are not
approved or authorized
for home or residential
use, but are intended for
commercial applications
only. Garland will not
provide service, warranty,
maintenance or support
of any kind other than in
commercial applications
Gas input ratings shown
here are for installations
up to 2,000 Ft. (610m)
above sea level. Specify
altitudes over 2,000 Ft.
G*
MIN: 6"
[152mm]
MAX: 9"
[229mm]
TOP
HEATER
11-1/2"
[292mm]
GRILL PLATE 24" X 36"
[610mm X 914mm]
24"
[610mm]
12-5/8"
[321mm]
GAS INLET*
47"
[1192mm]
FLARED BUCKETS
40-3/16"
[1021mm]
STRAIGHT BUCKETS
1-3/4"
[44mm]
FLUE OUTLETS*
TOP VIEW
FRONT VIEW
RIGHT SIDE VIEW
61-1/4"
[1556mm]
3/4"
GAS INLET*
35-5/8"
[905mm]
36-1/8"
[918mm]
26-3/16"
[665mm]
GRILL
PLATE
HEIGHT
TOLERANCE
+/- 1/8"
[3mm]
33-7/8"
[860mm]
11-3/16"
[284mm]
GAS INLET*
38 1/2"
[978mm]
* GAS MODELS ONLY
Clearances (all models)
Entry Installation
Crated Uncrated Sides Rear
47-1/2"
(1207mm)
40-3/4"
(1035mm)
6"
(152mm)
3"
(76mm)
Gas Pressure (XG models)
Total Gas Input
(XG models)
Supply (min.) Operating
NAT PRO NAT PRO BTU/Hr kW
7.0" WC 7.0” WC 3.5" WC 3.5” WC 99,000 29.1