FMI MM39/44/49VF Outdoor Fireplace User Manual


 
7
Forconventionalframing,wheretheoorjoistsareparallel
withthesidesoftherebox,theadditionofoorjoiststoalign
with the anchor brackets allows the brackets to be directly
connectedtotheoorjoists.
Notethatadditionaloorjoistsmayberequiredtosupport
theweightofthereboxandchimney.Wheretheoorjoistsrun
paralleltothefrontoftherebox,anchoragecanbeaccomplished
inlikemannerasshowninFigure5usingblockingbetweenthe
oorjoist.
ForoorssupportedbyI-Joists,themethodofanchorageis
illustratedinFigures6and7.Figure10illustratesthegeneral
arrangementofanchoragetooorframing.
Itisimportanttotakeintoconsiderationthattheloadforthe
Grand Meridian Fireplace must be considered as additional
deadloadthatwillhavetobesupportedbytheoorframing.
AdditionaloorjoistsorI-joistsmayberequiredasdetermined
bythelicenseddesignprofessional.
ThedeadweightsforthereplacearenotedinTableI.Itis
thetaskandresponsibilityofthegeneralcontractor/installerto
seethattheproperreinforcementforweightloadsaremadeby
alicenseddesignprofessionalpriortothereplaceinstallation.
Asstatedabove,itisdesirabletoplaceadditionalframing
foralignmentofanchorrods.RefertoFigure10foranchorrod
locations.
Figure 5
FloorSheathing
notshownfor
clarity
Anchor Bracket
Assembly
EXAMPLE ONLY
2X FLOOR JOIST
2X FLOOR JOIST
A35Brackets
(16required)
I-Joist
Simpson
Strong-Tie
A-35 or
equivalent
Figure 6
I-JoistAnchoring
TopView
Example Only
I-JOISTS
Anchor
Brackets
Figure 7
I-Joist
Anchoring
Bottom
View
Example Only