Desa VsGF28PTF Outdoor Fireplace User Manual


 
www.desatech.com
119303-01A
18
LIGHTING
INSTRUCTIONS


-



   
    

  
    
 

1.
STOP! Read the safety information, page 17.
2. Make sure equipment shutoff valve is fully
open.
3. Turn control knob clockwise to the
OFF position (see Figure 27).
4. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the oor.
If you smell gas, STOP! Follow “B” in the
safety information, page 17. If you don’t
smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position. Press in control
knob for ve (5) seconds (see Figure 27).
Note: If running replace for rst time,
there will be air in gas line. You may need
to press in control knob for 30 seconds or
longer. This will allow air to bleed from the
gas system.
6. Continue pressing control knob in. Press
and release ignitor button. This will light
pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor
button until pilot lights.
Figure 27 - Control Knob and Ignitor
Button Location
Ignitor Button
Control
Knob
OPERATING FIREPLACE
Continued
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 19.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7. This replace has a safety inter-
lock system. Wait one (1) minute for system
to reset before lighting pilot again.
• If control knob does not pop out when
released, contact a qualied service person
or gas supplier for repairs.
8. Turn control knob counterclockwise
to desired heating level. The burners should
light. Set control knob to any heat level
between HI and LO.
CAUTION: Do not try to ad-


Figure 28 - Pilot
Ignitor
Electrode
Pilot Burner
TO TURN OFF GAS


Turn control knob clockwise to the OFF
position.

Turn control knob clockwise to the
PILOT position.
THERMOSTAT CONTROL

You can set the thermostat control knob to any
comfort level between HI and LO. The thermo-
stat will gradually modulate the heat output
and ame height from higher to lower settings
or pilot, in order to maintain the comfort level
you select. The ideal comfort setting will vary
by household depending upon the amount of
space to be heated, the output of the central
heating system, etc.
Note: Selecting the HI setting will cause the
burner to remain on without modulating down
in most cases.