Desa VsGF28PTF Outdoor Fireplace User Manual


 
www.desatech.com
119303-01A
13


   
    




   

-


   



WARNING: Never connect

   
    

INSTALLATION
Continued
Installation Items Needed
Before installing replace, make sure you have
the items listed below.
external regulator for propane/LP unit only
(supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection *
sediment trap (optional)
tee joint
pipe wrench
approved exible gas line with gas connector
(if allowed by local codes) (not provided)
* A CSA design-certied equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certied equipment shutoff valve from your
dealer. See Accessories, page 26.
For propane/LP units, the installer must supply
an external regulator. The external regulator will
reduce incoming gas pressure. You must reduce
incoming gas pressure to between 11" and 14" of
water. If you do not reduce incoming gas pres-
sure, heater regulator damage could occur. Install
external regulator with the vent pointing down
as shown in Figure 17. Pointing the vent down
protects it from freezing rain or sleet.
CAUTION: Use only new,
     -


     




13"
16"
19"
21"
2
1
/
2
"
6"
8"
10"
Minimum Non-
Combustible
Material
Figure 16 - Minimum Mantel Clearances
for Built-In Installation
Mantel Shelf
Note:
All Vertical
measurements
are from top of
replace opening
to bottom of
mantel shelf.
Propane/LP
Supply Tank External
Regulator
Figure 17 - External Regulator With Vent
Pointing Down
Vent
Pointing
Down