Desa VsGF28PTF Outdoor Fireplace User Manual


 
www.desatech.com
119303-01A
15

-
   
and external to unit, for leaks
-

WARNING: Never use an

   
    
 

INSTALLATION
Continued
Figure 20 - Attaching Flexible Gas Lines
Flexible Gas Line
from Fireplace
Gas Regulator
To Fireplace
Gas Regulator
Equipment
Shutoff Valve
Provided by
Installer

To External
Regulator
Natural Gas
To Gas Meter
   
    



-


4. Attach the exible gas line to gas supply (see
Figure 20). Check tightness of exible gas
line attached to gas regulator of replace (see
Figure 20).
5. Check all gas connections for leaks. See
Checking Gas Connections, page 16.
6. Replace log base assembly back into replace.
Feed exible gas line into replace base area
while replacing log base assembly. Make sure
the entire exible gas line is in replace base
area. Reattach log base assembly to replace
with screws removed in step 2.




1. Disconnect replace with its main gas valve
(control valve) and equipment shutoff valve
from gas supply piping system. Pressures
in excess of 1/2 psig will damage replace
regulator.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas
or using compressed air.
4. Check all joints of gas supply piping system.
Apply noncorrosive leak detection uid to all
joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect replace and equipment shutoff
valve to gas supply. Check reconnected ttings
for leaks.


1. Close equipment shutoff valve (see Figure 21).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas
or using compressed air.
3. Check all joints from gas meter to equipment
shutoff valve for natural gas or propane/LP
supply to equipment shutoff valve for propane/
LP (see Figures 22 and 23, page 16). Apply
noncorrosive leak detection uid to all joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
Figure 21 - Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff Valve