Desa VMH26TNC Outdoor Fireplace User Manual


 
www.desatech.com
113111-01E26

 
 
 

 -

 
IMPORTANT: Operating replace where impurities in air exist may create odors. Cleaning supplies,
paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes.
These fumes may mix with combustion air and create odors.

1. Fireplace burning vapors from
paint, hair spray, glues, etc.
(See IMPORTANT statement
above)
2. Low fuel supply (propane/LP)
3. Gas leak.  

1. Not enough fresh air is avail-
able
2. Low line pressure
3. ODS/pilot is partially
clogged
1. Gas leak.  

2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas leak.  

1. Not enough combustion/ven-
tilation air
REMEDY
1. Ventilate room. Stop using
odor causing products while
replace is running
2. Rell supply tank
3. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 18)
1. Open window and/or door for
ventilation
2. Contact local propane/LP or
natural gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, page 22)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 18)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 18)
1. Refer to Air for Combustion
and Ventilation requirements
(page 6)

Fireplace produces unwanted
odors
Fireplace shuts off in use (ODS
operates)
Gas odor even when control
knob is in OFF position
Gas odor during combustion
Moisture/condensation noticed
on windows
TROUBLESHOOTING
Continued