Desa (V)KC36PE Outdoor Fireplace User Manual


 
www.desatech.com
116238-01D 23
FIREPLACE
INSTALLATION
Continued


and connections , internal and








PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM


1. Disconnect replace and its individual equip-
ment shutoff valve from gas supply piping
system. Pressures in excess of 1/2 psig (3.5 kPa)
will damage replace gas regulator.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas replace or opening main gas
valve located on or near gas meter for natural
gas replace or using compressed air.
4. Check all joints of gas supply piping system.
Apply noncorrosive leak detection uid to all
joints. Bubbles forming show a leak. Correct
all leaks at once.
5. Reconnect replace and equipment shutoff
valve to gas supply. Check reconnected ttings
for leaks.


1. Close equipment shutoff valve (see Figure 33).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas replace or opening main gas
valve located on or near gas meter for natural
gas replace or using compressed air.
3. Check all joints from propane/LP supply tank
or gas meter to equipment shutoff valve (see
Figure 34, for propane/LP or Figure 35, for
natural gas). Apply noncorrosive leak detec-
tion uid to all joints. Bubbles forming show
a leak. Correct all leaks at once.
Figure 33 - Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff Valve
Figure 34 - Checking Gas Joints for
Propane/LP Gas Fireplace
Propane/LP
Supply Tank
Gas Valve
Equipment Shutoff Valve
Figure 35 - Checking Gas Joints for
Natural Gas Fireplace
Gas
Meter
Gas Valve
Equipment
Shutoff Valve
Figure 32 - Connecting Flexible Gas Line
to Electronic Valve
1/2" NPT
Incoming
Gas Line
Inlet
Pressure
Tap
Outlet
Pressure
Tap
Equipment
Shutoff
Valve
Flexible
Gas Line
Do NOT
Kink
Note: Wire Connections Not Shown for Clarity
Red Surface
Indicates For
Propane/LP Use
Only