DCS BGB30-BQR Gas Grill User Manual


 
12
GENERAL:
Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete
gas tightness check must be performed at the installation site due to possible mishandling in
shipment, or excessive pressure unknowingly being applied to the unit. Periodically check the whole
system for leaks, or immediately check if the smell of gas is detected.
Before Testing:
Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle,
brush,or rag to apply the solution to the fittings. For LP units,check with a full cylinder. The valve panel
must be removed to check the valves and fittings. Remove the knobs and the safety valve knob,then
remove the 4 screws which fasten the valve panel to the unit (you will need a torx head for this). Pull
the valve panel outward and unplug the wires from the ignition module and the back of the ignition
button. Remove the screws which hold the service panel in place.
To Test:
Make sure all control valves are in the“OFF” position. Turn the gas supply“ON”. Check all connections
from the supply line, or LP cylinder up to and including the manifold pipe assembly. Apply the soap
solution around the connection, valve, tubing and end of the manifold. Soap bubbles will appear
where a leak is present. If a leak is present, immediately turn off gas supply, tighten any leaking
connections,turn gas on, and recheck. Check all the gas connections at the base of the control valves
where they screw into the manifold pipe.
To check rotis burner and safety valve the burner must be lit, then leak test the connections located
behind the service panel. If you cannot stop a gas leak turn off the gas supply and call your local gas
utility, or the dealer you purchased the appliance from. Only those parts recommended by the
manufacturer should be used on the Grill. Substitution can void the warranty.
WARNING :
Do not use the grill until all connections have been checked and do not leak.
Check all gas supply fittings for leaks before each use. It is handy to keep a spray bottle of soapy water near
the shut-off valve of the gas supply valve. Spray all the fittings. Bubbles indicate leaks. (Fig. 05 & 06)
Bottom of unit
LEAK TEST POINTS
LP TANK
CHECK HOSE FOR
SIGNS OF ABRASIONS,
CRACKS, OR LEAKS
Bottom of unit
LEAK TEST POINTS
LEAK TESTING
FIG.05 LP Gas
FIG.06 Nat.Gas