Cal Flame Barbeque Grill Gas Grill User Manual


 
Page 8 2007 Barbecue Grill and Cart Owner’s Manual
LTR20071038, Rev. B
Installation / Assembly
One side of the enclosure shall be completely
open.
Enclosures that have four sides, complete with a
top and bottom:
At least two ventilation openings at cylinder
valve level shall be provided in the sidewall,
equally sized, spaced at 180º (3.14 rad), and
unobstructed. Each opening shall have a total
free area of not less than one square inch per
pound (7.1 cm²/kg) of stored fuel capacity, and
not less than a total free area of 10 square
inches (64.5 cm²).
Ventilation openings shall be provided at oor
level and shall have a total free area of not less
than one square inch per pound (7.1 cm²/kg)
of stored fuel capacity and not less than a
total free area of 10 square inches (64.5cm²).
If ventilation openings at oor level are in a
sidewall, there shall be at least two openings.
The bottom of the openings shall be at oor
level and the upper edge no more than 5
inches (127 mm) above the oor. The openings
shall be equally sized, spaced at 180º (3.14
rad) and unobstructed.
Every opening shall have minimum dimensions
so as to permit the entrance of a 1/8 inch (3.2
mm) diameter rod.
Transporting and Storing LP Gas
Transport only one cylinder at a time. Ensure the
cylinder is secured in an upright position with the
control valve turned off and the dust cap in place. Store
cylinders outdoors and out of reach of children. Do
not store cylinders in a building, garage, or any other
enclosed area.
1.
2.
a.
b.
c.
LP Gas
Tank Requirements
For plumbed-in LP installation, use a
convertible regulator and set it for LP
gas.
Maximum line pressure for plumbed-
in propane is 14” WC (3.5 kPa).
Minimum line pressure for propane is
11” WC.
The grill unit must be used with the
gas pressure regulator. The regulator
will control and maintain a uniform
gas pressure in the manifold. The burner orices
have been sized for the gas pressure delivered by the
regulator.
WARNING: Attempting to operate the grill unit without
the gas regulator installed could cause an explosion
and possible death.
Cylinder Specication
Any LP gas supply cylinder used with this grill must be:
Constructed and marked in accordance with the
Specications for LP-Gas Cylinders of the U.S.
Department of Transportation or the National
Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of
Dangerous Goods; and Commission, as applicable.
Approximately 12 inches in diameter and 18 inches
high.
The maximum fuel capacity is 20 lbs. of propane, or 5
gallons. Full cylinder weight should be approximately
38 lbs. (43.7 lbs. nominal water capacity.) Never ll the
cylinder beyond 80% full.
Place the dust cap on the cylinder valve outlet
whenever the cylinder is not in use. Only install the type
of dust cap on the cylinder valve outlet that is provided
with the cylinder valve. Other types of caps or plugs
may result in leakage of propane.
LP Gas Hook Up
An enclosure for an LP gas cylinder shall be vented by
openings at the level of the cylinder valve and at oor
level. The effectiveness of the openings for purposes of
ventilation shall be determined with the LP-gas supply
cylinder in place. This shall be accomplished in one of
the following manners: