Cal Flame Barbecue Grills & Carts Gas Grill User Manual


 
2009 Barbecue Grills and Carts
LTR20091038, Rev. A
Installation / Assembly
www.calspas.com
7
Natural Gas
Requirements
Always check the rating plate to make sure the gas
supply you are hooking up to is the gas type the grill
is manufactured for.
IMPORTANT: Never connect the grill to an unregulated
gas supply.
The installation of this appliance must conform
with local codes or, in the absence of local codes,
to the national fuel gas code, ANSI Z223.1a-1998.
Installation in Canada must be in accordance with
the standard CAN/CGA-B149.2, Propane Installation
Code.
A licensed contractor or local gas company
representative must perform all natural gas
connections.
Ensure that the service supplying the grill is tted
with a shut off valve conveniently positioned near the
grill and giving ease of access.
The grill must be isolated from the gas supply piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 0.5 psi
(3.5 kPa).
The grill and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressure in excess of 0.5 psi (3.5 kPa).
Your Cal Flame™ grill for use with natural gas comes
equipped with its own regulator that MUST NOT
be removed. If, this regulator needs to be replaced
use only the type specied by Cal Flame™ for this
appliance.
Connection
Remove the rear panel from the barbecue to 1.
gain access to the regulator and gas connection
point.
Connect a suitable ex connector to the grill 2.
regulator.
Check the grill controls to ensure all control valves 3.
are in the full OFF position.
Turn on the main gas supply and check all 4.
connections for leaks using soapy water as
described in the leak testing procedure section.
Warning: If you see bubbles in the soapy solution at
any of the connections, turn off the gas supply and
tighten the connection. If tightening the connection
does not seal the leak, it may be necessary to replace
the ex hose.