Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
2009 Barbecue Grills and Carts
LTR20091038, Rev. A
Installation / Assembly
www.calspas.com
6
One side of the enclosure shall be completely 1.
open.
Enclosures that have four sides, complete with a 2.
top and bottom:
At least two ventilation openings at cylinder a.
valve level shall be provided in the sidewall,
equally sized, spaced at 180º (3.14 rad),
and unobstructed. Each opening shall have
a total free area of not less than one square
inch per pound (7.1 cm²/kg) of stored fuel
capacity, and not less than a total free area
of 10 square inches (64.5 cm²).
Ventilation openings shall be provided at b.
oor level and shall have a total free area of
not less than one square inch per pound (7.1
cm²/kg) of stored fuel capacity and not less
than a total free area of 10 square inches
(64.5cm²). If ventilation openings at oor
level are in a sidewall, there shall be at least
two openings. The bottom of the openings
shall be at oor level and the upper edge no
more than 5 inches (127 mm) above the oor.
The openings shall be equally sized, spaced
at 180º (3.14 rad) and unobstructed.
Every opening shall have minimum c.
dimensions so as to permit the entrance of a
1/8 inch (3.2 mm) diameter rod.
Transporting and Storing LP Gas
Transport only one cylinder at a time. Ensure the
cylinder is secured in an upright position with the
control valve turned off and the dust cap in place.
Store cylinders outdoors and out of reach of children.
Do not store cylinders in a building, garage, or any
other enclosed area.
LP Gas
Tank Requirements
For plumbed-in LP installation, use a
convertible regulator and set it for LP
gas.
Maximum line pressure for plumbed-in
propane is 14” WC (3.5 kPa). Minimum
line pressure for propane is 11” WC.
The grill unit must be used with the
gas pressure regulator. The regulator
will control and maintain a uniform gas
pressure in the manifold. The burner orices have
been sized for the gas pressure delivered by the
regulator.
WARNING: Attempting to operate the grill unit
without the gas regulator installed could cause an
explosion and possible death.
CylinderSpecication
Any LP gas supply cylinder used with this grill must
be:
Constructed and marked in accordance with •
the Specications for LP-Gas Cylinders
of the U.S. Department of Transportation
or the National Standard of Canada, CAN/
CSA-B339, Cylinders, Spheres and Tubes
for Transportation of Dangerous Goods;
and Commission, as applicable.
Approximately 12 inches in diameter and 18 •
inches high.
The maximum fuel capacity is 20 lbs. of propane, or 5
gallons. Full cylinder weight should be approximately
38 lbs. (43.7 lbs. nominal water capacity.) Never ll
the cylinder beyond 80% full.
Place the dust cap on the cylinder valve outlet
whenever the cylinder is not in use. Only install the
type of dust cap on the cylinder valve outlet that is
provided with the cylinder valve. Other types of caps
or plugs may result in leakage of propane.
LP Gas Hook Up
An enclosure for an LP gas cylinder shall be vented by
openings at the level of the cylinder valve and at oor
level. The effectiveness of the openings for purposes
of ventilation shall be determined with the LP-gas
supply cylinder in place. This shall be accomplished
in one of the following manners: