Teledyne IGE 3000 Charcoal Grill User Manual


 
IGE 300 Page 5 of 21
1. Quick Start Information
Apply Power
Apply 24 VDC Power to the “D” connector Pin 3 and 4.
After power is applied the IGE 3000 will go through self test, CPU initialization, and LED test.
(The individual LEDs will sequentially illuminate then the IGE 3000 enters the “No Mode” and
is operational).
Operate Tube
Before operating tube, ensure vacuum is below 1x10-2 Torr. The IGE 3000 has an automatic shutoff
feature that will not allow filament turn on at pressures above 1x10-2 Torr. The shutoff feature will also
automatically turn off the filament if it is turned on (below 1x10-2 Torr) and pressure rises above 1x10-2
TO TURN ON THE TUBE’S FILAMENTS:
“DOUBLE CLICK” the select button. (note: Double clicking the SELECT button while the
filament is already On will turn it OFF).
Initially dashes will remain on the display. However, as the tube heats up and starts operating, within
seconds the pressure will be displayed. LED’s (F1 or F2) will be illuminated, indicating which filament is
selected and that it is turned on.
F2
Fil
F1High Low
KSP
Emis DGas
2X=On/Off