Teledyne IGE 3000 Charcoal Grill User Manual


 
IGE 300 Page 16 of 21
6.4. Data Bits/Parity Bits/Stop Bits
P8n1
The first character, “8” corresponds to the number of data bits. (e.g. 7 or 8).
Second character, “n” corresponds to the parity bit. (i.e. n- no parity, E- even parity, o- odd parity, 0-
space, 1- mark)
The last character, “1” corresponds to the number of stop bits. (e.g. 1 or 2)
8n1, 8n2, 7n2, 7E1, 7E2, 7o1, 7o2, 701, 702, 711,712
Note: There is no equivalent RS232/485 command.
6.5. Turnaround Delay
dt06
dt00, dt01, ...dtFE, dtFF
The turnaround delay is unique to multipoint communications. It is the delay between receipt of an
incoming command to transmission of the response. Each increase in the hex value corresponds to an
increase in the delay time of approximately 8 ms.
Note: Equivalent RS232/485 command. *{aa}T={dd}<CR>
6.6. Save EEPROM
S_EE
EEW<CR>
This command stores setting data to EPROM memory.
Note: There is no equivalent RS232/485 command
6.7. Restore EEPROM
r_EE
EER<CR>
Note: There is no equivalent RS232/485 command