Nexgrill 720-0008-T Gas Grill User Manual


 
Safety Instructions
Pipe sealing compound or pipe thread tape of the
type resistant to the action of natural gas must be
used on all male pipe threads when making the
connection.
3
Disconnect your gas grill from fuel source when
the gas supply is being tested at high pressures.
This appliance and its individual shut off valve
must be disconnected from the gas supply piping
system during any pressure testing of that
system at pressure in excess of 1/2 psi(3.5kpa)
Turn off your gas grill when the gas supply is
being tested at low pressure. This appliance
must be isolated from the gas supply piping
system by closing its individual manual shut off
valve during any pressure testing of the gas
supply piping system at pressures equal or less
than1/2 psi(3.5kpa)
WARNING: Gas valves are preset at factory to
operate on LP or nature gas. If you wish to
convert, be sure to contact your grill dealer
FIRST!
S
S
A
A
F
F
E
E
T
T
Y
Y
!
!
BEWARE
OF
SPIDERS
CAUTION:BURNER TUBES MUST
B
INSPECTED AND CLEANED BEFO
R
FIRST USE
spiders and small insects Occasionally spin
webs or make nests in the burner tubes
during warehousing and transit. These
webs can lead to a gas flow obstruction,
which could result in a fire in and around
the burner tubes. This type of fire is known
as “FLASH-BACK” and can cause serious
damage to your grill and create an unsafe
operating condition for the use. Although
an obstructed burner tube is not the only
cause of “FLASH-BACK” it is the most
common cause and frequent inspection and
cleaning of the burner tubes in necessary.
NATURAL GAS SAFETY(FOR natural
gas model)
Your natural gas grill is designed to operate on 7’’
water column residential (1/4 psi or 1.75 kpa)
regulate at the residential meter, Check with your
gas utility for local gas pressure and with your
local municipality for building code requirements.
If your residential gas utility line pressure has not
been regulated to 7’’ W.C. contact your local gas
utility or gas grill dealer for professional
assistance.
Check with your gas utility or with local building
codes for instructions to install gas supply line, or
call a licensed and knowledgeable installer.
It is recommended that an “ON-OFF” shut off
valve be installed at the gas supply source;
outdoors after gas line piping exits outside wall
and before quick-disconnect or before gas line
piping enters ground indoors in the branch fuel
line in an accessible location near the supply line.