Martin Fireplaces BV5142 Fire Pit User Manual


 
GAS LINE AND ELECTRICAL INSTALLATION
GAS LINE AND ELECTRICAL INSTALLATION
18
Turn RS-ON-OFF switch to the “ON” position.
If meter is reading more than 175 millivolt and the main burner does not come on, then replace
control valve.
If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this
manual to determine the cause of the low reading.
Turn RS-ON-OFF switch to the “RS ” position and wall switch to “ON”
If meter is reading more than 175 millivolt and the main burner does not come on, then replace
control valve.
If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this
manual to determine the cause of the low reading.
Electronic Pilot Ignition Wiring:
WARNING
Do not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfunction or be destroyed.
Figure 14: Wiring Diagram for Electronic Ignition System
Remote Wall Switch
Position the wall switch. Refer to Figure 14: Wiring Diagram for Electronic Ignition System. Do not extend
beyond the 15 feet of wire.
Optional DC Remote Systems
These instructions supersede the section entitled “Hearth Mount” in the Millivolt hand held remote
instructions supplied with the remote.