Martin Fireplaces BV5142 Fire Pit User Manual


 
VENT INSTALLATION
VENT INSTALLATION
12
Figure 8: Installing Pipe Supports
WARNING
Always maintain minimum clearances around vent systems. The minimum clearances to combustibles is 1”
around vent pipe. For ceiling firestops and vertical sections of vent pipe a 1-inch minimum clearance all
around the pipe must be maintained. Do not pack the open air spaces with insulation or other materials. This
could cause high temperatures and may present a fire hazard.
NOTE
A ceiling firestop MUST BE installed if the vent passes through a ceiling. Refer to the instructions from the
pipe manufacturer.
To Locate and Install Ceiling Firestop
For ceiling firestops, position a plumb bob over the center of the vertical pipe; to spot a hole through
which the pipe will penetrate.
Drill a hole through this center point and check the floor for obstructions (i.e. wiring or plumbing).
Reposition the fireplace and vent system, if necessary, to accommodate ceiling joists or obstructions.
Cut a 11-inch by 11-inch hole through the ceiling, using the center point.
Frame the hole with framing lumber the same size as the ceiling joists. Refer to the Figure 9. Position
firestop as shown in the Figure 9. If attic is above, mount firestop on top of framing. If room is above,
mount firestop on the bottom of framing. Secure with nails or screws.
Run vent through firestop.