Lennox Hearth ADAGIO-MN Outdoor Fireplace User Manual


 
30
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 53 - Burner Flame Appearance
* Vent to combustible
on Side = 1" Min.
Vent to combustible
on Top = 3" Min.
IMPORTANT NOTE:
Place the header verti-
cal as shown to main-
tain proper clearance
from the vent system to
combustibles.
Figure 54
Fireplace (right side)
1" Min.
(25 mm)*
4" Min
(102 mm)*
This Area Must
Remain Clear of
Combustible Materials
Top of
Appliance
Header
(2x4)
Drywall
Spacers
FINISHING REQUIREMENTS - Wall Details
Complete finished interior wall. To install the appliance facing flush with
the finished wall, position framework to accommodate the thickness of
the finished wall (Figure 54).
u
4" clearance is required above the elbow for installations that require an
elbow at the top of the unit and that ends in a horizontal termination.
Hearth Extension
A hearth extension is not required with this appliance. If a hearth extension
is used, do not block the lower control compartment panel. Any hearth
extension used is for appearance only and does not have to conform to
standard hearth extension installation requirements.