Hearth and Home Technologies 36 Outdoor Fireplace User Manual


 
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN • 4039-156 Rev K 7/11
12
72 in./183 cm
min.
TR11/TR444
Termination
Cap
A. Install the Dual Cooling Air Kit
The cooling air kit is supplied as a standard feature with this
replace and is required for safe operation. Installation must
be done at the time of initial construction. The cooling air in-
let tubes must be a minimum of 72 in. (1829 mm) above the
base of the replace to prevent potential blockage by snow
or yard debris. See Figure 4.1.
To install the air kit collar, slide one of the tabs down into the
seam. See Figure 4.2. Secure the collar tabs to the replace
with screws placed into the holes provided. See Figure 4.3.
Repeat for other side.
Sharp Edges
Wear protective gloves and safety glasses
during installation.
CAUTION
4
Installation of Fireplace
Fire Risk
Asphyxiation Risk
Do not draw outside combustion air from:
Wall, oor or ceiling cavity.
Enclosed space such as an attic or
garage.
Close proximity to exhaust vents or
chimneys.
Fumes or odor may result.
WARNING
Figure 4.1 Cooling Air Location
Figure 4.2 Slide the Tabs
Figure 4.3 Secure the Tabs
Note: The cooling air kit must terminate at least 6 ft. (1.83 m)
above ground level.