E. Chimney Requirements
When planning your replace location, the chimney construc-
tion and necessary clearances must be considered. The re-
place system and chimney components have been tested to
provide exibility in construction. The following gures are
the minimum distances from the base of the replace.
Minimum overall straight height is 6 ft 4 in. if the replace
is freestanding and a minimum of 10 ft from a combustible
structure. See Figure 3.2.
Chimney must extend 2 ft (.6 m) above any portion
of the roof within 10 ft (3 m) of the chimney. Refer to
Figure 6.1.
Note: A maximum of two pairs of offsets and returns may
be used.
ft m
Minimum heightwith offset/return 16 4.88
Maximum height 90 27.43
Maximum chimney length between an offset
and return
20 6.1
Maximum distance between chimney
stabilizers
35 10.67
Double offset/return minimum height 24 7.32
Maximum unsupported chimney length
between the offset and return
6 1.83
Maximum unsupported chimney height above
the replace
35 10.67
Minimum overall straight height if replace is