Hearth and Home Technologies Dakota 42-CE Outdoor Fireplace User Manual


 
20 Heat & Glo Lifestyle Collection • Dakota 42-CE • 4036-915 Rev I • 1/07
Although the frequency of replace servicing and maintenance will depend on use and the type of installation, a quali ed
service technician should perform an replace check-up at the beginning of each heating season.
Debris from any outside source and/or soot must be removed from the eplace. Allow logs to cool, remove if necessary,
vacuum and replace in accordance with instructions on pages 13-15.
Annual inspection by qualified technician
recommended.
Check:
Condition of doors, surrounds and fronts.
Condition of glass, glass assembly.
Obstructions of combustion and ventilation
air.
Condition of logs.
• Condition of rebox.
Burner ignition and operation.
Burner air shutter adjustment.
Gas connections and ttings.
Clean:
• Glass.
Air passageways, grilles, control
compartment.
Burner, burner ports.
Risk of:
Fire
Delayed ignition or explosion
Exposure to combustion fumes
• Odors
WARNING
Handle glass assembly with care.
Note: Clean glass after initial 3-4 hours
operation. Longer operation without
cleaning glass may cause a permanent
white lm on glass.
When cleaning glass door:
Avoid striking, scratching or slamming
doors.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on
white lm.
Do NOT clean glass when it is hot.
• Turn off replace after 3-4 hours of operation
and ALLOW TO COOL.
Remove and clean glass assembly.
Replace glass assembly and operate
replace for an additional 12 hours.
Refer to maintenance instructions.
CAUTION
11
11
Maintaining and Servicing the Fireplace
Risk of injury or property damage
Before servicing:
Turn off gas.
Disable remote control, if one is present.
• Ensure replace is completely cooled.
After Servicing:
Replace any screen or barrier that was removed.
Reseal and reinstall any venting removed for
servicing.
WARNING