Enviro 50-1628 Fire Pit User Manual


 
14
Initial Installation
QUALIFIED INSTALLERS ONLY
WARNING: Operation of this heater when not connected to a properly installed and maintained venting
system can result in carbon monoxide (CO) poisoning and possible death.
PREPARATION FOR INSTALLATION:
• If you are converting to a Cara DR unit, follow the instructions in this Manual, especially
referencing the Conversion and Venting sections.
• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is
found, please report it to both the carrier and your dealer as soon as possible.
• Before beginning, carefully check the glass door and the log set
• Locate a position where the ue system of the stove can be properly installed without damaging the
integrity of the building; e.g. cutting a wall or ceiling joist.
• Check stove and ue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
• As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8
m) of the stove.
• The ow of combustion and ventilation air must not be obstructed.
CLEARANCES TO COMBUSTIBLES:
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.
Table 3: Clearance to Walls in an Open Area, refer to Figure 23.
Letter Description Clearance
A Sidewall to unit 11 inches (279 mm)
B Backwall to unit 2.5 inches (64 mm)
C Corner to unit 2.5 inches (64 mm)
D Ceiling to oor 90 inches (2286 mm)
E Floor (on hardwood and linoleum) 0 inches (0 mm)
Figure 23: Clearance to Walls in an Open Area, refer
to Table 3.
Table 4: Clearance to Walls in an Alcove
Description Clearance
Minimum Width 43 inches (1105 mm)
Minimum Height 48 inches (1219 mm)
Maximum Depth 24 inches (610 mm)
B
A
Back Wall
Side Wall
C
Adja
cen
t Wal
l