Desa VTGF33PRB Outdoor Fireplace User Manual


 
www.desatech.com
113134-01B
8
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top Left and Bottom
Right Sides and Rear
0" 16" 0"
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri
-
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified ser-
vice person must install fire
-
place. Follow all local codes.
WARNING: Never install the
fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the fireplace
• in high traffic areas
• in windy or drafty areas
CAUTION: This fireplace
creates warm air currents. These
currents move heat to wall sur
-
faces next to fireplace. Installing
fireplace next to vinyl or cloth
wall coverings or operating
fireplace where impurities (such
as, but not limited to, tobacco
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps,
etc.) in the air exist, may discolor
walls or cause odors.
Note: Your fireplace is designed to be used in zero
clearance installations. Wall or framing material
can be placed directly against any exterior surface
on the rear, sides, or top of your fireplace, except
where standoff spacers are integrally attached. If
standoff spacers are attached to your fireplace,
these spacers can be placed directly against wall
or framing materials.
Use the dimensions shown for rough openings to
create the easiest installation (see Built-In Fire
-
place Installation, page 17).
IMPORTANT:
Vent-free heaters add moisture to
the air. Although this is beneficial, installing fire
-
place in rooms without enough ventilation air may
cause mildew to form from too much moisture. See
Air for Combustion and Ventilation,
page 5.
IMPORTANT: Make sure the fireplace is level. If
fireplace is not level, log set will not work properly.
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP)
for your unit. If your gas supply is not correct, do
not install fireplace. Call dealer where you bought
fireplace for proper type fireplace.
WARNING: This appliance
is equipped for (natural or pro-
pane/LP) gas. Field conversion
is not permitted.
ELECTRICAL HOOKUP
This fireplace normally operates under 120
VAC/60 Hz line voltage. The electrical cord sup
-
plied with your fireplace is five feet in length. You
must locate fireplace within reach of a 120 volt
grounded electrical outlet. If not, you must install
an electrical outlet within reach of the fireplace
power cord. The GA3555 outlet accessory may
be used for built-in applications.
INSTALLATION CLEARANCES
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling, and adjoining wall.