Desa (V)TC36N(-HA) Series, (V)TC36P(-HA) Series Outdoor Fireplace User Manual


 
www.desatech.com
116192-01G30

This feature allows the user to lock/unlock the
keypad on the hand-held remote in the MANU or
AUTO mode to prevent inadvertent operation (i.e.
children operating the hand-held remote control,
etc.). The keypad is locked in either on or off. Press
the POWER and LOCK buttons together to turn
the unit on or off.
OPERATING OPTIONAL
GWMT1 - WALL MOUNTED
THERMOSTAT
WARNING: Do not con-



Light the replace as instructed in Lighting
Instructions on page 27. Set wall thermostat to
desired temperature.
This thermostat has been electronically cali-
brated at the factory and requires no adjust-
ment or leveling.
Upon installation, the thermostat must be al-
lowed to stabilize at room temperature for a
minimum of 30 minutes for proper operation.
To turn the replace off, adjust thermostat to
the lowest setting and turn the gas control knob
back to PILOT. The pilot will remain lit.
IMPORTANT: To turn the pilot off, turn the
gas control knob on the heater to the OFF
position.
OPERATING OPTIONAL

Locate the blower controls by opening the lower
louver panel on the replace. Blower controls
are located on the right side of the switch
bracket to the left just inside the louver panel.
The BK manual blower and the BKT thermo-
statically-controlled blower have an ON setting
and an OFF setting. The blower will only run
when the switch is in the ON position. In the
OFF position, the blower will not operate.
OPERATING FIREPLACE
Continued
Note for BKT Only: If you are using BKT
blower with optional thermostat (wall mounted
or remote control) for the replace, your re-
place and blower will not turn on and off at the
same time. The replace may run for several
minutes before the blower turns on. After the
heater modulates to the pilot position, the blow-
er will continue to run. The blower will shut off
after the rebox temperature decreases.
The blower helps distribute heated air from
the replace. Periodically check the louvers of
the rebox and remove any dust, dirt or other
obstructions that will hinder the ow of air.
INSPECTING bURNERS
Check pilot ame pattern and burner ame pat-
terns often.

The pilot assembly is factory preset for the proper
ame height. Alterations may have occurred dur-
ing shipping and handling. Call a qualied service
person to readjust the pilot if necessary.
The height of the thermopile must be 3/8" to 1/2"
above the pilot ame as shown in Figure 49. The
thermocouple must be at a height of about 1/8"
above the pilot ame. The ame from the pilot
burner must extend beyond both the thermocouple
and thermopile.
If you pilot assembly does not meet these require-
ments:
turn replace off (see To Turn Off Gas to Ap-
pliance, page 28)
see Troubleshooting, page 33
Thermocouple
Thermopile
1/8"
Pilot Burner
Piezo
Ignitor
Figure 49 - Pilot Assembly
3/8" to 1/2"