Desa (V)CD36TN Outdoor Fireplace User Manual


 
www.desatech.com
116035-01E44
REPLACEMENT PARTS
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized retailers of this product. If
they can not supply original replacement part(s),
call DESA’s Customer Service Department at
1-866-672-6040.
When calling DESA, have ready
your name
your address
model and serial numbers of your replace
how replace was malfunctioning
type of gas used (propane/LP or natural gas)
purchase date
Usually, we will ask you to return the part to the
factory.
PARTS NOT UNDER WARRANTY
Contact authorized retailers of this product. If
they can not supply original replacement part(s),
call DESA at 1-866-672-6040 for referral infor-
mation.
When calling DESA, have ready
model number of your replace
the replacement part number
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
replace will not produce specied heat
propane/LP gas supply might be low (propane/
LP units only)
You may feel your gas pressure is too low. If so,
contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA’s
Customer Service Department at 1-866-672-6040.
When calling, please have your model and serial
numbers of your heater ready.
You can also visit DESA’s technical service web site at
.
SPECIFICATIONS

Rating: 15,000/21,000 Btu/hr
Gas Type: Natural Gas Only
Ignition: Millivolt
Manifold Pressure: below 2000 ft. elevation -
3.5" w.c. (0.87 kPa), above 2000 ft. elev. - 3.8"
(0.94 kPa)
Orice Size (Main Burner): #44 DMS (0.086")
Minimum Inlet Supply Pressure: 5.5" w.c.
(1.1 kPa)
Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurement):
35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

Rating: 13,000/20,000 Btu/hr
Gas Type: Propane/LP Gas Only
Ignition: Millivolt
Manifold Pressure: 10.0" w.c. (2.5 kPa)
Orice Size (Main Burner): #55 DMS (0.052")
Minimum Inlet Supply Pressure: 11.0" w.c.
(2.7 kPa)
Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurement):
35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

Rating: 21,000 Btu/hr
Gas Type: Natural Gas Only
Ignition: Electronic
Manifold Pressure: below 2000 ft. elevation -
3.5" w.c. (0.87 kPa), above 2000 ft. elev. - 3.8"
(0.94 kPa)
Orice Size (Main Burner): #44 DMS (0.086")
Minimum Inlet Supply Pressure: 5.5" w.c.
(1.1 kPa)
Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurement):
35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

Rating: 20,000 Btu/hr
Gas Type: Propane/LP Gas Only
Ignition: Electronic
Manifold Pressure: 10.0" w.c. (2.5 kPa)
Orice Size (Main Burner): #55 DMS (0.052")
Minimum Inlet Supply Pressure: 11.0" w.c.
(2.7 kPa)
Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurement):
35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)