Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
www.desatech.com
116035-01E18
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figures 28 and 29 show two different congura-
tions for vertical termination.
VERTICAL VENT INSTALLATIONS USING
MULTIPLE 90° ELBOWS (V)CD36R REAR
VENT
Figure 28 - Vertical Venting
Conguration using One 90° Elbow
(Model (V)CD36R with Vertical Round
High Wind Termination)
Figure 29 - Vertical Venting
Conguration using Three 90° Elbows
(Model (V)CD36R with Vertical Round
High Wind Termination)
1
Horizontal
(H
1
1
2
Horizontal (H
2
8' Min. 2' Max. 12' Min. 8' Max
8' Min. 2' Max. 14' Min. 11' Max
8' Min. 2' Max. 16' Min. 14' Max
8' Min. 2' Max. 18' Min. 17' Max
8' Min. 2' Max. 20' Min. 20' Max
8' Min. 2' Max. 40' Min. 20' Max
Note: Vertical (V
1
) + Vertical (V
2
) = 40' Max.
Max. Horizontal Above 20' Vertical = 20'
8' Min. 2' Max
40' Min. 2' Max
90°
Elbow
90°
Elbow
90°
Elbow
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination
cap.
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination
cap.