Desa CDCFTN Fire Pit User Manual


 
www.desatech.com
111244-01C
23
OPERATING FIREPLACE
Continued
OPERATING
BLOWER
This blower has three settings: ON, OFF, and
AUTO. In the ON position, the blower will op-
erate constantly. In the OFF position, the
blower will not operate. In the AUTO position,
the blower will start when the thermostat senses
a sufficient increase in firebox temperature.
Note:
Your fireplace and thermostat blower
will not turn on and off at the same time. The
fireplace may run for several minutes before
the blower turns on. After the heater modulates
to the pilot position, the blower will continue to
run. The blower will shut off after the firebox
temperature decreases.
Note:
It is safe to operate fireplace with blower
turned off. However, the blower helps distrib-
ute heated air from the fireplace.
Figure 38 - AUTO/OFF/ON Blower Switch
AUTO/OFF/ON Switch
REMOTE-READY MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
LIGHTING
INSTRUCTIONS
WARNING: You must oper-
ate this fireplace with the screen
in place. Make sure fireplace
screen is installed before run-
ning fireplace.
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.
WARNING: Burner will come
on automatically within one
minute when control valve is in
the ON position after the pilot is lit.
1. STOP! Read the safety information start-
ing in column 1.
2. Make sure equipment shutoff valve is fully
open.
3. Press in and turn control knob clockwise
Clockwise
to the OFF position (see Figure 39,
page 24).
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information, column 1. If you don’t
smell gas, go to the next step.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and
to replace any part of the control system and
any gas control which has been under water.