Shutting Off Appliance
Turn gas shutoff valve clockwise to the
OFF position.
CURING
LOGS
During the 2-3 hour appliance break-in period,
you may detect an odor from the appliance
as the various paints and compounds used in
the manufacturing of this log set cure. This is
a normal and temporary situation that is not
cause for alarm. However, you may want to
provide extra ventilation to the room during
this time.
To ensure proper curing of the logs:
Ignite a 2" flame and maintain it for 1
hour.
Burn the logs in consecutive 1 hour periods
raising the flame an additional 2" to full
flame height for a total of three hours.
OPERATING
INSTRUCTIONS
FOR GA9050A
Note: Operation instructions for GA9150A
Remote Ready Valve/Pilot Kit will be included
with the kit.
1. STOP! Read the safety information, page 10.
2. Make sure equipment shutoff valve is fully
open.
3. Press in and turn control knob clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas around log set and near
floor. If you smell gas, STOP! Refer to the
National Fuel Gas Codes, ANSI Z233.1/
NFPA 54, Section 5.3, Air for Combustion
and Ventilation. If you donʼt smell gas, go
to the next step.
5. Turn control knob counterclockwise
to the PILOT position and press in. Keep
control knob pressed in for five (5) seconds.
Note: You may be running this log set for
the first time after hooking up to gas sup
-
ply. If so, the control knob may need to be
pressed in for 30 seconds. This will allow
air to bleed from the gas system.
• If control knob does not pop up when
released, contact a qualified service person
or gas supplier for repairs.
OPERATING APPLIANCE
Continued
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the rear of
the front burner. If needed, keep pressing
ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7.
8. Turn control knob counterclockwise
to the ON position. Burner should light. If
burner does not light, call a qualified service
person.
Ignitor
Control Knob
Pilot
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
TO LIGHT
ON
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
TO LIGHT
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
TO LIGHT
ON OFF
On
Off
OFF
OFF
Figure 12 - Ignitor and Control Knob
Figure 13 - Thermocouple and Pilot
Pilot
Burner
Thermocouple
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Appliance
1. Turn control knob clockwise to the
PILOT position.
2. Press in and turn control clockwise
to the OFF position.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
to the
PILOT position.