Desa LCF24 Outdoor Fireplace User Manual


 
www.desatech.com
115043-01C
10
INSTALLATION
Continued
Figure 11 - Installing Top Logs
Figure 10 - Installing Middle Logs
OPERATING APPLIANCE
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: Keep flue open
when operating unit.
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per
-
sonal injury or loss of life.
BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighborʼs phone. Follow the gas supplierʼs
instructions.
If you cannot reach your gas supplier, call
the fire department.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information, above.
2. Turn the gas shutoff valve to OFF.
3. Wait five (5) minutes to clear out any gas. If
you then smell gas STOP! Follow the safety
information above. If you don't smell gas,
go on to the next step.
4. Light a match and lay it on top of the pan
material about 2" from the end of the sup
-
ply side of the pan
5. Slowly turn the gas shutoff valve ON until
the burner ignites. If the burner doesnʼt
ignite within 10 seconds with the match
burning, turn the shutoff valve OFF and
repeat steps 1 through 4 again.
GAS SHUTOFF
VALVE OPERATION
Flame Adjustment
Adjust the flame ON/OFF by turning the gas
shutoff valve counterclockwise to open or
clockwise to close, as necessary.