CFM Corporation SHR52 Outdoor Fireplace User Manual


 
16
SHR Series Woodburning Fireplace
20001384
FP1167
facing flush
with finished wall
12/20/01 djt
Finished Wall
Stud
Noncombustible
Decorative Fac-
ing
Must be Sealed with
Noncombustible
Material
Surround
2 x 4 Finished
Header
Covered Wall
Ledge Bracket
FP1167
Fig. 27 Facing on fireplace surround flush with finished wall.
FP1168
finishing front
12/20/01 djt
CAUTION: Do Not
Place Finishing Ma-
terial Beyond These
Edges or Cover Air
Inlets
Screen Rail
Hearth
FP1168
Fig. 28 Finishing front of fireplace.
MA81
rev. 8/5/97
rev. 4/18/01
1"
Ref.
*
* *
MA81
Fig. 29 Combustible mantel clearances.
Face Plate
* 12" from top of fireplace opening.
** 6" from top of fireplace opening. (Noncom-
bustible material must separate the black face
surround of the fireplace and any combustible
mantel material)
Combustible materials are permit-
ted within a shaded area shown
in Figure 32 titled Minimum Wall
Clearances