Glen Dimplex Home Appliances Ltd BI 70 G Gas Grill User Manual


 
Data badge
Lower part of front frame and the rear
panel of the appliance.
Pressure setting
Natural Gas G20 @ 20 mbar (8”wg)
Gas category
Natural gas - I2H
Appliance class
Class 3 built in double oven and grill
Ignition
Mains operated re-ignition generator
Electrical supply
220 - 240V ~ 50Hz
Main oven
Bray type burner, sheet steel body,
stainless steel flame strip
Nominal Rate Qn 2.5kW
Injector 1.25mm
Spark gap 3 - 4mm
Thermostat bypass 50
Oven injector - If the injector is
removed or replaced for any reason, it
is mandatory to apply Hylomar PL32
or Plasticol X10 sparingly to the thread
prior to (re)fitting.
Top oven
Nominal rate Qn 1.8kW
Injector 130 amal
Spark gap 3 - 4mm
Thermostat bypass 50
Oven injector - If the injector is
removed or replaced for any reason, it
is mandatory to apply Hylomar PL32
or Plasticol X10 sparingly to the thread
prior to (re)fitting.
Maximum heat input
Qn 4.75kW
Countries of destination
GB - Great Britain
IE - Ireland
37
Technical Data