Glen Dimplex Home Appliances Ltd BI 70 G Gas Grill User Manual


 
Step 6: Commissioning
Pressure test point
Use the oven burner. From inside the
oven remove the burner cowl. Remove
the small screw at the LHS of the
burner cradle. Slide the burner to the
left to access the injector. Connect
manometer to the injector and turn the
grill burner to full on to check pressure.
Replace in reverse order.
Burner aeration
All burners have fixed aeration and no
adjustment is possible.
Pressure setting
G20 Natural Gas @ 20 mbar
Electrical systems check
In the event of an electrical fault the
preliminary electrical system check
(earth continuity, short circuit, polarity
and resistance to earth) must be
carried out.
Ignition
The automatic ignition continues to
spark for a short time after the burner
has lit until the flame is established.
Oven (Top and Main)
Push in and turn the main oven control
knob anti clockwise to the
FULL ON
position (gas mark 9). The ignition
system will spark automatically. Push
in the control knob to ignite the gas.
The sparking will stop. If after 15
seconds, the burner has not lit, turn off
the oven and leave the compartment
door open. Wait at least one minute
before a further attempt to ignite the
burner.
Do not hold the control knob in for
more than 15 seconds.
Turn the control knob clockwise to the
required setting.
To turn off, return the control knob to
the “off” position.
Grill
1. The door must be open for grilling.
2. Push in and turn the control knob
clockwise to the grill symbol.
When you first turn on the oven or
grill you may notice a smell and some
smoke which comes from the
protective coating of oil burning off
from some of the parts.
Before leaving the installation
Show the customer how to use the
oven and grill, and give them this
handbook. Thank you.
36
Installation Instructions