Aussie 69F6U00KS1 Gas Grill User Manual


 
12
How to Perform A Leak Test “FIRST TIME USE” and as required
Supplies Needed for a Leak Test:
• Clean paint brush • Water • Dish washing liquid • Clean container
1. Use an LP Gas Cylinder equipped with an OPD (Overfill Prevention Device) and have it filled at an authorized LP
gas dealer by a qualified attendant.
2. Make sure all grill Control Panel Knobs are turned to the “Off” position and verify that the LP Gas Cylinder valve is
closed by turning the knob on the LP Gas Cylinder clockwise until it stops.
3. Mix one part of water with one part of dish washing liquid.
4. If already in place, remove the cooking grids and flavor activators. Open the Control Panel from the Grill Body/
Firebox by removing the four bolts from that attach the top of the control panel to the top of the firebox. (Fig. 1)
Carefully lower Control Panel away from the Body until Valves disengage from the Tubular burner ends. The bolts
in the bottom ends of the control panel act as hinge points. The control panel will stop opening at the horizontal
position.
5. With the regulator hose connected to the LP Gas Cylinder, turn the knob on the Cylinder counterclockwise. (Fig. 2).
Fig. 2
Fig. 1
Coupling
Nut
Check for leaks at
Cylinder Valve and
Regulator Connection
and Fittings
Fig. 3
Screws inside front
face of Firebox