American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control Outdoor Kitchen Island User Manual


 
Fig. 2
1. Determine location of ENCLOSURE (1). It must be
located with-in the 14" (356mm) by 21" (533mm)
shaded area shown in Fig. 2 in order for electrical
connections from the spout assembly to be made.
NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance
between wall supply and ENCLOSURE (1) must be
taken into consideration.
2. Remove 4 screws from COVER (2) and pull off
COVER (2). Hold the ENCLOSURE (1) in desired
location and mark the four mounting hole locations as
shown. Fig. 2.
3. The ENCLOSURE (1) works best if secured to a wall
stud or cross brace within the wall, using the SCREWS
(3) supplied. If the ENCLOSURE (1) is to be installed on
a tile or plaster wall the ANCHORS (4) and SCREWS
(3) should be used.
4. For installations on drywall or tiled walls; use
ANCHORS (4) and SCREWS (3) for securing
ENCLOSURE (1) to finished wall. Drill four 1/4" dia.
holes a minimum of 1-3/4" deep. Insert the four
ANCHORS (4) flush with face of the finished wall.
Align the ENCLOSURE (1) and Install the MOUNTING
SCREWS (3). Tighten to secure ENCLOSURE (1) to
mounting surface.
1524mm
(60)
14"
(356mm)
3-3/4"
(96mm)
2-3/4"
(71mm)
3"
(76mm)
21"
(mm)
2
4
3
1
1
1
20"
(500mm)
MOUNTING HOLES
SUPPLIES
WASTE
ENCLOSURE
MOUNTING
HOLES
LAVATORY RIM OR
MOUNTING SURFACE
3
MOUNT ENCLOSURE; Fig. 2
2
1. Connect SUPPLY NUT (1) from spout assembly to
nipple on top of ENCLOSURE (2). Tighten with
adjustable wrench to make a water tight connection.
Fig. 3.
CONNECT SPOUT HOSE TO
ENCLOSURE; Fig. 3
CONNECT HOSES TO WALL
SUPPLY; Fig. 4
3
4
3
33
Fig. 4 Fig. 4a
2
2
2
1
4
1
1. Insert FIBER WASHERS (4) into SUPPLY NUTS (1)
on ENCLOSURE (2). Fig. 4.
2. Connect SUPPLY NUT (1) on ENCLOSURE (2) to
FLEXIBLE SUPPLY HOSE (3). Tighten to make a
water tight connection. Use two wrenches if necessary.
Fig. 4a.
3. Connect FLEXIBLE SUPPLIES (3) corresponing to the
red dot on ENCLOSURE (2) to the hot water supply,
and the FLEXIBLE HOSE (3) corresponding to the blue
dot to cold water supply. Connection on FLEXIBLE
SUPPLIES (3) are 3/8" compression. Use adjustable
wrench to tighten connection. Do not over tighten.
FIG. 4b.
Note: FLEXIBLE SUPPLY (3) measures 20" from the
bottom of the ENCLOSURE (2) base. If additional
supply length is required, installer must purchase
parts separately.
Important: If FLEXIBLE SUPPLIES (3) are too long, loop
to avoid kinking.
COLD
RED
DOT
BLUE
DOT
COLD
HOT
HOT
Fig. 4b
Fig. 3
1
2