maintenance
REPLACE MAIN BURNERS
1) Your Summit
®
gas grill must be off and cool.
2) Turn gas off at source.
3) Disconnect gas supply.
4) Remove cooking grates.
5) Remove smoker box.
6) Remove Flavorizer
®
bars.
REMOVE CONTROL PANEL
Part required: Phillips Screwdriver.
Remove the burner control knobs (a).
Remove the two screws that secure the control panel to the frame (b).
Remove the control panel. Tilt panel forward and lift up and away from grill (c).
a
c
b
MAIN BURNER CLEANING PROCEDURE
TURN OFF THE GAS SUPPLY.
Remove the manifold (See “Replacing Main Burners”).
Look inside each burner with a flashlight.
Clean the inside of the burners with a wire (a straightened-out coat hanger will work).
Check and clean the air shutter opening at the ends of the burners. Check and clean
the valve orifices at the base of the valves. Use a Steel bristle brush to clean outside of
burners. This is to make sure all the burner ports are fully open.