Weber SUMMIT GRILL CENTER Gas Grill User Manual


 
10
www.weber.com
®
3
1
2
7
6
4
5
Gas instructions
Check:
1) Main gas line to manifold connection.
2) Rotisserie (I.R. Burner) gas line connection.
3) Bulkhead and gas supply hose connection.
4) Bulkhead to regulator connection.
5) Regulator to hose connection.
m WARNING: If there is a leak at connection (1, 2, 3, 4, or 5),
retighten the fitting with a wrench and recheck for leaks with
soap and water solution.
If a leak persists after re-tightening the fitting, turn off the gas.
DO NOT OPERATE THE GRILL. Contact the Customer Service
Representative in your area using the contact information on
our web site. Log onto www.weber.com
®
.
6) Gas supply to shutoff connection.
7) Valvestomanifoldconnections.
m WARNING: If there is a leak at connections (6 or 7), turn
off the gas. DO NOT OPERATE THE GRILL. Contact the
Customer Service Representative in your area
using the contact information on our web site.
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply off at the source and
rinse connections with water.
REINSTALL CONTROL PANEL
Parts required: control panel, screws and burner control knobs.
Hook the top edge of the control panel onto the control panel brackets
on either side of the front of the cooking box.
Line up screws with screw holes on both the control panel bracket and
the frame. Tighten screws.
Place corresponding control knobs onto the valve stems.
* The grill illustrated may have slight
differences than the model purchased.